Model No. |
GP-CVP150P-12V-T01 |
GP-CVP150P-24V-T01 |
GP-CVP150P-36V-T01 |
GP-CVP150P-48V-T01 |
輸出 |
直流電壓 |
12V |
24V |
36V |
48V |
額定電流 |
200~264VAC |
0~11.0A |
0~6.25A |
0~4.2A |
0~3.15A |
100~180VAC |
0~10.0A |
0~5.0A |
0~3.35A |
0~2.5A |
額定功率 |
200~264VAC |
132W |
150W |
151.2W |
151.2W |
100~180VAC |
120W |
120W |
120.6W |
120W |
紋波和噪音(Max.) |
200mV |
200mV |
360mV |
480mV |
效率(Typ.) |
89% |
91% |
91% |
91.5% |
電壓精度 |
± 5% |
± 5% |
± 5% |
± 5% |
啟動時間(Max.) |
≦0.5S at 230VAC, full load. |
輸入 |
額定電壓 |
100 ~ 240VAC 141~340VDC |
電壓範圍 |
90 ~ 264VAC |
頻率範圍 |
47 Hz ~ 63 Hz |
交流電流(Max.) |
1.3A at 115VAC / 0.8A at 230VAC |
功率因數 |
>0.98 at 115VAC / >0.95 at 230VAC, full load. |
總諧波失真 |
THD < 10% at 230VAC, full load |
浪湧電流(Typ.) |
Cold Start 55A (Td=630us measured at 50% Ipeak) at 230VAC |
斷路器可配置同型號
電源供應器數量 |
B type : 2 units (10A) / 3 units (16A) / 5 units (25A),
C type : 3 units (10A) / 5 units (16A) / 9 units (25A),
D type : 11 units (16A) / 18 units (25A) at 230VAC |
漏電流 |
<1mA at 240VAC |
空載功耗 |
< 0.5W at 230VAC (0.3W Typ.) |
保護功能 |
過電流 |
200~264VAC |
110%~150% |
110%~150% |
110%~150% |
110%~150% |
100~180VAC |
130%~185% |
130%~185% |
130%~185% |
130%~185% |
|
Type: Hiccup mode (Auto recover after fault condition disappeared). |
短路 |
Type: Hiccup mode (Auto recover after fault condition disappeared). |
過電壓 |
13.2V~18V |
26.4V~36V |
39.6V~54V |
52.8V~72V |
Type: Hiccup mode (Auto recover after fault condition disappeared). |
過溫度 |
Tcase: 90°C ± 10°C |
Type: Shut down output , recovers automatically after temperature goes down. |
其他 |
MTBF |
100K hours min. MIL-HDBK-217F(25°C) |
尺寸重量 |
204 x 53.5 x 30mm; 540 g/pcs |