| Model No. |
GP-FA-2407
AC Plug Type ; U=US AC Plug , K=UK AC Plug , E= EU AC Plug, A=Australia AC plug |
Output
(Charging
Mode) |
Charge Voltage |
32Vdc +/-2% @ Boost mode
28.8Vdc +/-2% @ Normal mode ( Bulk Stage)
29.4Vdc +/-2% @ Snow mode (when temperature under 0°C and AGM batteries use only) (Bulk Stage)
|
| Charge Current Range |
2A / 4A / 7A by optional |
| Rated Maximum Power |
200W |
| Efficiency |
> 85% @ note1 |
| Charging Mode |
Mode1 |
Boost : 32V , 80% output current charging the battery. |
| Mode2 |
Normal : Charging in the norm. |
| Mode3 |
Snow : Charging it when ambient temperature under 0°C and only use for AGM batteries. |
Output
(Supply
Mode) |
Output Voltage |
27V DC |
| Output Voltage tolerence |
+/- 2% |
| Output current |
2A / 4A / 7A |
| Output current tolerence |
+/- 10% |
| Output Mode |
Constant Voltage and Constant Output Current . |
| Input |
Input Voltage range |
100 ~ 240Vac |
| Input frequency range |
47~63Hz |
| Input current rating |
3A |
| Protections |
Polarity Reverse |
YES,except for Supply mode. (No Charge and Fault-LED ON till fault has removed) |
| Disconnect |
YES,except for Supply mode. (No Charge and sparks when the output clips disconnected or short) |
| Over Temperature |
Output shutdown and Fault-LED ON . |
| Short Circuit |
YES. (No Charge until output short has removed) |
| Wrong Battery Protection |
YES. (No Charge When Vbat<2V or Vbat>15V) |
| Environment |
Operating Temperature |
-20~40°C |
| Operating Humidity |
10~95% RH. |
| Vibration |
10~500HZ,2G/P-P,3 axes,15min sweep without malfunction. |
| Shock |
20G/Package |