October 29, 2020 - Taipei, Taiwan - GlacialPower, the power division of the LED technology manufacturer GlacialTech Inc, announces the new GP-CVP060N-12VL and GP-CVP075N-24VL LED constant voltage driver are suitable for low voltage areas. They are available in 12V DC output rated power of 60 W and 24V DC output rated power of 76.8 W. These drivers support TRIAC dimming function, and appropriate for LED strips and under-cabinet lights application in places such as restaurants, jewelry shop, home and theater.
The dimming adjustment output of the GP-CVP060N-12VL and GP-CVP075N-24VL LED drivers range from 5% to 100%. They provide a smooth dimming curve and without flicker. The drivers feature AC phase-cut dimming also compatible with leading edge and trailing edge TRIAC dimmers for a wide range of applications. As well as fulfill the AC dimming requirement in the LED lighting market. Both the typical power conversion efficiency is 83%. They support an AC input voltage range from 108 to 132 V AC.
The fully isolated case design enables an operation temperature range of -20°C to 50°C, means that LED driver can be used in most environments. Additionally, with IP65 approval as well as four different protections: Over-Voltage Protection (OVP), Over-Current Protection (OCP), Short-Circuit Protection (SCP) and Over-Temperature Protection (OTP), these drivers are highly secure and equipped with a long design lifetime. |
Model No. |
GP-CVP060N-12VL-P02 |
GP-CVP075N-24VL-P02 |
Output |
Voltage Range |
12VDC |
24VDC |
Ripple & Noise (Max.) |
0.6Vp-p |
0.7Vp-p |
Voltage Tolerance |
± 5% |
± 5% |
Dimming Range |
5%~100% |
5%~100% |
Rated Current |
5A |
3.2A |
Rated Power |
60W |
76.8W |
Efficiency (Typ.) |
83% |
|
Set up Time (Max.) |
0.5S / 120VAC at full load |
Input |
Rated Voltage |
120VAC |
Voltage Range |
108~132VAC |
Frequency Range |
50/60 Hz |
AC Current (Typ.) |
1.2A at 120VAC |
1.5A at 120VAC |
Power Factor |
> 0.5 at 120VAC with full load. |
Inrush Current (Typ.) |
Cold Start 55A (Td=568us measured at 50% Ipeak) at 120VAC |
Max. Number of PSUs
on Circuit Breaker |
B type : 2 units (10A) / 3 units (16A) / 6 units (25A),
C type : 4 units (10A) / 6 units (16A) / 10 units (25A),
D type : 12 units (16A) / 20 units (25A) at 120VAC |
Leakage Current (Typ.) |
<1mA / 120VAC |
Protections |
Over Voltage |
120 % - 150% Output voltage limiting, auto-recovery |
Over Current |
120% - 150% Hiccup mode, recovers automatically after fault condition is removed |
Over Temperature |
110°C - 120°C Temperature limiting, auto-recovery |
Short Circuit |
Hiccup mode, recovers automatically after fault condition is removed |
Others |
MTBF |
100K hours min. @Ta=25°C |
Dimension(L x W x H) |
138 x 47 x 32 mm; 385g/pcs |
|