February 02, 2021 - Taipei, Taiwan - GlacialPower, the power division of the LED technology manufacturer GlacialTech Inc, announces the new GP-CCP040P series LED constant current driver. At full load the new series provides an outstanding active power factor correction (PFC) which greater than 0.95 at 115Vac, and more than 0.9 at 230Vac. It has low no-load power consumption under 0.5 watt and a fast set-up time under 0.5 second at 230Vac. The GP-CCP040P series provides wide voltage range (Vf) from 12V to 52V, especially focus on 36V CoB market. Combines the GP-CCP040P with the GP-HS series, GlacialPower offers the constant current solutions for 36V CoB from 150mA, 200mA, 230mA, 250mA, 270mA, 300mA, 350mA, 420mA, 450mA, 480mA, 500mA, 600mA, 660mA, 700mA, 800mA, 1050mA, 1200mA to 1400mA.
The GP-CCP040P series supports universal AC input between 90 and 264Vac, it comes in an IP67 rated dust and waterproof enclosure suitable for outdoor as well as indoor use. It includes protections of over voltage (OVP) and short circuiting (SCP) to prevent the product’s damage and ensure the quality. Its power efficiency is up to 86%. The GP-CCP040P series is compliant with CE certificate by LED driver product segment, and fully complies with ErP (EU) 2019/2020 regulations to reduce the product’s impact on the environment to improve sustainability. |
Model No. |
GP‐CCP040P‐
40C-P02 |
GP‐CCP040P‐
52C-P02 |
GP‐CCP040P‐
52C1-P02 |
GP‐CCP040P‐
52C2-P02 |
GP‐CCP040P‐
52C3-P02 |
Output |
DC Voltage |
40V |
52V |
52V |
52V |
52V |
Constant Current Region |
12 ~ 40V |
22 ~ 52V |
22 ~ 52V |
22 ~ 52V |
22 ~ 52V |
Rated Current |
1.05A |
0.8A |
0.7A |
0.6A |
0.5A |
Rated Power |
42W |
41.6W |
36.4W |
31.2W |
26W |
Ripple & Noise (Max.) |
300mV |
300mV |
300mV |
300mV |
300mV |
Efficiency (Typ.) |
84% |
86% |
86% |
85% |
84% |
Current Tolerance |
± 5% |
± 5% |
± 5% |
± 5% |
± 5% |
Set up Time (Max) |
< 0.5S / 230VAC, at full load. |
Input |
Rated Voltage |
100 ~ 240VAC |
Voltage Range |
90 ~ 264VAC |
Frequency Range |
47 Hz ~ 63 Hz |
AC Current (Typ.) |
0.48A at 115VAC,
0.24A at 230 VAC |
0.48A at 115VAC,
0.24A at 230VAC |
0.42A at 115VAC,
0.22A at 230VAC |
0.36A at 115VAC,
0.18A at 230VAC |
0.30A at 115VAC,
0.16A at 230VAC |
Power Factor |
>0.95 at 115VAC, >0.9 at 230VAC at full load. |
Total Harmonic Distortion |
THD < 10% at 230VAC, full load. |
No-Load Power Consumption |
< 0.5W at 230VAC |
Inrush Current (Typ.) |
Cold Start 25A (Td=40us measured at 50% Ipeak) at 230VAC |
Max. Number of PSUs on Circuit Breaker |
B type : 21 units (10A) / 34 units (16A) / 53 units (25A),
C type : 21 units (10A) / 34 units (16A) / 53 units (25A),
D type : 34 units (16A) / 53 units (25A) at 230VAC |
Leakage Current (Typ.) |
<1mA / 230VAC |
Protections |
Short Circuit |
Type: Recovers automatically after fault condition is removed |
Over Voltage |
44V~60V |
57.2V~78V |
57.2V~78V |
57.2V~78V |
57.2V~78V |
Type: Output Voltage limiting, auto-recovery |
Others |
MTBF |
100K hours min. MIL-HDBK-217F(25°C) |
Dimension(L x W x H) |
110 x 35 x 25mm; 156g/pcs |
|